山東西瓜影视動力承接(jiē)電站建設業務 POWER STATION CONSTRUCTION。

電站(zhàn)建設
一、電(diàn)站(zhàn)建設注意事項 Notice about Power plant construction

◎ 機房一般采用敞開式或是半開式(shì),采用不發生火花的(de)地麵,地麵平整易於清理。
◎ 如果采用閉式機房,應按(àn)《建築設計防火規範》(TJ16-74)中防爆設計要求設計,必須是單層建(jiàn)築,門窗(chuāng)一律外開,設置大流量排放裝置,防止(zhǐ)燃氣體積聚集。
◎ 機房與操作間應隔開,不得(dé)直接連通(tōng),觀察窗應雙層玻璃,且有鋼絲網防護。
◎ 必須有避雷裝置。
◎ 配備充足的(de)滅火設(shè)備。
◎ 機房現場不能有明火(huǒ),必須有明顯的“嚴(yán)禁煙火”等警示標誌。
◎ 發電機組排出的(de)廢氣中,可能混有少量可燃氣體,要(yào)設計安裝由發(fā)動機引向室外的排氣管,排氣管係統應(yīng)連接(jiē)可靠。
◎ Generator Room is usually constructed in open or semi-open type. The floor of generator room should be easily to clean and not easily to spark.
◎ If you want to construct closed generator room. You must construct a single-storey building. The open direction of all the doors and windows must turn outside. Please install some big capacity displacement device to avoid gas gathering.
◎ Generator room and the operation room must be separated, can not be directly connected. The observation window should be with double- deck glass protected by steel wire mesh.
◎ Lightning arrester is necessary.
◎ Prepare enough fire extinguishing appliances.
◎ "No Fire" mark should be obvious, open flame in the generator room is not allowed.
◎ In the exhaust gas, there might be a small amount of combustible gas. So the exhaust pipe of the generator must be leaded to outside of room. The exhaust pipe must be connected tightly.

二、機(jī)房設備要求 Requirements for the Equipments in Generator Room
◎機(jī)房內的電氣設備必須(xū)防爆(bào),進行維修時,必須切斷電源。
◎在燃氣管(guǎn)道進房(fáng)處,設置(zhì)緊急閥門,以備廠房發生緊急(jí)情況時(shí),可迅速切斷氣源,此閥門應離操作間很近。
◎要有氣體檢(jiǎn)測(cè)報警係(xì)統,以檢測漏氣問題。
◎ Electric equipments in the generator room must be explosion proof. When you repair the equipments, must turn off the power.
◎ Fix an urgent valve at the intake where gas pipe is leaded into room. You can cut off the gas in time if it’s emergency. This valve should be close to the operation room.
◎ The alarm system of gas detecting is necessary to find out the gas leakage in time.

三、燃氣管道要求(qiú) Requirements for Gas pipe
◎燃氣(qì)管道要(yào)求用無縫鋼管(guǎn),管壁不應過薄,接頭處必須密封(fēng)可靠,管道連接後要用燃(rán)氣檢測儀或是肥皂水檢測管線滲漏情況。
◎定期檢查閥門和管道,應無(wú)燃氣泄漏情況、無管道破損情況。
 
◎ All the gas pipes should adopt seamless steel tube, the pipe well should not be very thin, the connector of pipe should be sealed tightly. After connecting, please detect the leakage situation by gas detector or soap suds.
◎ Check the valve and pipe regularly, make sure there is no leakage and breakage situation.